The wishlist name can't be left blank
This website requires cookies to provide all of its features. By using our website, you agree to our use of cookies - Learn more - Accept
Your web browser (Internet Explorer) is no longer supported
Update browser More information
My Cart 0
quality
quality Approved & certified
service
service 24x7 The foundation of our service
flexible
flexible Also custom made seals
support
+31 (0)38 - 30 32 700

Do you want to order for the first time?

Request a Login

Already a customer?

Click here to sign in

Oil seal OS-A13

OS-A13

Description

  • Elastomer-coated OD, flat
  • Non-spring-loaded sealing lip 
  • Protective lip against entry of contamination from outside (dust, dirt,...) ribbed OD available on request, type OS-G13


Special features

  • Non-spring-loaded lip design, for secondary sealing jobs e.g., grease sealing
  • Low friction
  • Compact design
  • Little installation space
  • Reliable static sealing inside housing
  • For housings with high thermal expansion, e.g., light metal housing
  • For split housings
  • For housings with increased surface roughness
  • No risk of fretting corrosion
  • Efficient protection against air side contaminations


Applications e.g.:

  • Secondary sealing jobs
  • Mechanical and apparatus engineering
  • Drive systems
  • Electric motors


Materials

Standard material

Elastomer NBR 70 black
Metal case Carbon steel according to DIN EN 10139


Special materials

Elastomer FKM
Silicon
ACM
HNBR
CR
EPDM
Metal case Stainless steel 1.4301



Application parameters

For the standard materials combination:

Temperature  -40°C to +100°C                                                                                           
Pressure depressurized
Shaft speed max. 6 m/s, and acc. to chart „Operating parameters for rotary shaft seals“
Media Mineral oil based lubricants, synthetic lubricants


When synthetic lubricants are used for which there is no empirical experience, test the compatibility in the laboratory or - better even - in practical trials. The operating temperature should not exceed 80°C.



Design information

Shaft

Tolerance ISO h11
Hardness min. 45 HRC
Roughness Ra = 0,2 - 0,8 μm
Rz 1-5 μm 
Rmax ≤ 6,3 μm
Surface finish free of orientation (lead free)


Housing bore

Tolerance ISO H8
Roughness Ra = 1,6 - 6,3 μm 
Rz = 10 - 20 μm 
Rmax ≤ 25 μm



Installation

Please read our installation instructions.

Loading